Immersion Heaters HXRL Series
SUPERIOR CHEMICAL RESISTANCE: Inert to most aqueous acid, alkaline, anodizing and pickling solutions up to 212°F (100°C).
RUGGED CONSTRUCTION: Heavy wall fluoropolymer (PTFE) covered stainless steel element reduces permeation and eliminates the need for gas purged systems. Guaranteed 100% pinhole free.FLUOROPOLYMER PTFE) GUARDS SOLD SEPARATELY.
OUTSTANDING PERFORMANCE: Low watt density design (10 watts/square inch, 1.5 w/cm2) for long service life.
FLEXIBLE RISER: 4-foot (1.2m) continuous fluoropolymer (PTFE) cable leading to a vapor resistant PVC terminal enclosure and 3-foot (.9m) flexible PVC liquid tight conduit.
SAFETY FEATURES:
SIZES: 1,000 watts to 6,000 watts.
VOLTAGES: 120 to 600 volts. Single phase only.
RUGGED CONSTRUCTION: Heavy wall fluoropolymer (PTFE) covered stainless steel element reduces permeation and eliminates the need for gas purged systems. Guaranteed 100% pinhole free.FLUOROPOLYMER PTFE) GUARDS SOLD SEPARATELY.
OUTSTANDING PERFORMANCE: Low watt density design (10 watts/square inch, 1.5 w/cm2) for long service life.
FLEXIBLE RISER: 4-foot (1.2m) continuous fluoropolymer (PTFE) cable leading to a vapor resistant PVC terminal enclosure and 3-foot (.9m) flexible PVC liquid tight conduit.
SAFETY FEATURES:
- Grounded internal metal element.
- Thermal protector built in. Resettable P3 J-type thermocouple standard.
- Non-floating construction.
SIZES: 1,000 watts to 6,000 watts.
VOLTAGES: 120 to 600 volts. Single phase only.
Immersion Heaters HXSL Series
SUPERIOR CHEMICAL RESISTANCE: Inert to most aqueous acid, alkaline, anodizing and pickling solutions up to 212°F (100°C).
RUGGED CONSTRUCTION: Heavy wall fluoropolymer (PTFE) covered stainless steel element reduces permeation and eliminates the need for gas purged systems. Guaranteed 100% pinhole free.CUSTOM BUILT TO CONFORM TO TANK DIMENSIONS.FLUOROPOLYMER GUARDS SOLD SEPARATELY.
OUTSTANDING PERFORMANCE: Low watt density design (10 watts/square inch, 1.5 w/cm2) for long service life.
FLEXIBLE RISER: 4-foot (1.2m) continuous fluoropolymer (PTFE) cable leading to a vapor resistant PVC terminal enclosure and 3-foot (.9m) flexible PVC liquid tight conduit.
SAFETY FEATURES:
SIZES: 1,000 watts to 6,000 watts.
VOLTAGES: 120 to 600 volts. Single phase only.
RUGGED CONSTRUCTION: Heavy wall fluoropolymer (PTFE) covered stainless steel element reduces permeation and eliminates the need for gas purged systems. Guaranteed 100% pinhole free.CUSTOM BUILT TO CONFORM TO TANK DIMENSIONS.FLUOROPOLYMER GUARDS SOLD SEPARATELY.
OUTSTANDING PERFORMANCE: Low watt density design (10 watts/square inch, 1.5 w/cm2) for long service life.
FLEXIBLE RISER: 4-foot (1.2m) continuous fluoropolymer (PTFE) cable leading to a vapor resistant PVC terminal enclosure and 3-foot (.9m) flexible PVC liquid tight conduit.
SAFETY FEATURES:
- Grounded internal metal element.
- Thermal protector built in. Resettable P3 J-type thermocouple standard.
- Non-floating construction.
SIZES: 1,000 watts to 6,000 watts.
VOLTAGES: 120 to 600 volts. Single phase only.
Flange Heaters - FLX Series
SUPERIOR CHEMICAL RESISTANCE: Inert to most aqueous acid, alkaline, anodizing and plating solutions. Check solution recommendation chart or with your chemical supplier for proper sheath material selection.
RUGGED CONSTRUCTION:Heavy wall fluoropolymer (PTFE) covered stainless steel sheath reduces permeation and eliminates the need for gas purge systems. Guaranteed 100% pinhole free.
SAFETY FEATURES:
SIZES: 1,000 watts to 18,000 watts
VOLTAGES: 120 to 600 volts. 3FLX single phase standard, 6FLX single or three phase
RUGGED CONSTRUCTION:Heavy wall fluoropolymer (PTFE) covered stainless steel sheath reduces permeation and eliminates the need for gas purge systems. Guaranteed 100% pinhole free.
- Rated for up to 50 PSI service.
- Vapor resistant polypropylene head.
LONG-LASTING PERFORMANCE
SAFETY FEATURES:
- Grounded internal metal heating element
- Thermal protection built in. Replaceable P2 protector standard for solutions up to 180°F (82°C)
- Non-floating construction.
SIZES: 1,000 watts to 18,000 watts
VOLTAGES: 120 to 600 volts. 3FLX single phase standard, 6FLX single or three phase
Flange Heaters - FL Series
SUPERIOR CHEMICAL RESISTANCE: For use in most aqueous alkaline, plating solutions and rinse tanks. Check solution recommendation chart or with your chemical supplier for proper sheath material selection.
RUGGED CONSTRUCTION:
Heavy wall metal sheaths and flanges in:
CORROSION RESISTANT HEAD: Vapor resistant, painted metal enclosures.
SAFETY FEATURES:
SIZES:
RUGGED CONSTRUCTION:
Heavy wall metal sheaths and flanges in:
- 316 stainless steel
- Carbon steel
- Incoloy
- Titanium
CORROSION RESISTANT HEAD: Vapor resistant, painted metal enclosures.
SAFETY FEATURES:
- Grounded construction.
- Thermal protection built in. Replaceable P1 protector standard for solutions up to 180°F (82°C).
SIZES:
- 3,000 watts to 72,000 watts.
- 150 lbs. ASA flanges from 3-inch through 6-inch sizes.
Aplisens Pressure Transmitters
Pressure transmitters are applicable to the measurement of the pressure, under pressure and absolute pressure of gases, vapours and liquids.
PRESSURE TRANSMITTER APC-2000ALW
Pressure transmitters are applicable to the measurement of the pressure, underpressure and absolute pressure of gases, vapours and
liquids. The active sensing element is a piezoresistant silicon sensor separated from the medium by a diaphragm and by specially selected type
of manometric liquid. The casing is made of aluminium alloy cast or 316SS stainles steel, degree of protection IP66/IP67. The design
of the casing enables the use of a local display, rotation of the display, rotation of the casing by 0–340° relative to the sensor, and a choice of
cable direction.
PRESSURE TRANSMITTER APCE-2000PD and APCE-2000PZ
The APCE-2000 pressure transmitter is applicable to the measurement of the pressure, underpressure or absolute pressure
of gases, vapours and liquids. The active sensing element is a piezoresistant silicon sensor separated from the medium by
a diaphragm and by specially selected type of manometric liquid.
PRESSURE TRANSMITTER PCE-28
PCE-28 pressure transmitter is applicable to the measurement of the pressure, underpressure and absolute pressure
of gases, vapours and liquids. The active sensing element is a piezoresistant silicon sensor separated from the medium by
a diaphragm and by specially selected type of manometric liquid.
PRESSURE TRANSMITTER AS
The pressure transmitter AS is applicable to
measurement the pressure of gases vapours and
liquids. It may be applied in water supply systems
and heat engineering
PRESSURE TRANSMITTER APR-2000ALW
The APR-2000ALW transmitter is applicable to the measurement of differential pressure of gases, vapours and liquids. The active element is a
piezoresistant silicon sensor separated from the medium by separating diaphragms and a specially selected type of manometric fluid. The
special design of the active sensing element ensures that it is able to withstand pressure surges and overloads of up to 250/320/420 bar.The
casing is made of aluminium alloy cast or 316SS stainles steel, degree of protection IP66/IP67. The design of the casing enables the use of a
local display, rotation of the display, rotation of the casing by 0–340° relative to the sensor, and a choice of cable direction.
PRESSURE TRANSMITTER APR-2200ALW or APRE-2200
The differential pressure transmitter is applicable
to the measurement of pressure differences of: gases,
vapours and liquids in cases where it is necessary
to use seals and the pressure pulse source points may
be several metres apart. Typical applications include
the hydrostatic measurement of: levels in closed tanks,
densities and phase boundaries, and the measurement
of a filter loss, pressure differences between media
in pasteurisers etc. The available range of the diaphragm
seals allows measurement at great majority of
media. The active element is a piezoresistant silicon
sensor separated from the medium by a distance sealing
system. The special design of the measuring unit
means that it can withstand pressure surges and overloads
of up to 40 bar. The electronic circuits are enclosed
in a casing with a degree of protection IP 65
or IP66
PRESSURE TRANSMITTER APR-2000ALW diaphragm seals
Smart or analog differential pressure transmitters with diaphragm seals for level measurement to pressure tank with gas-filled negative pressure line are recommended transmitters with diaphragm seal mounted on "+" side to pressure tank with liquid-filled negative line are recommended transmitters with diaphragm seal mounted on "-" side and converted output signal.