level probe APC-2000ALW/L

The APC-2000ALW/L level probe is applicable to measure liquid levels in tanks, deep wells or piezometers. The APC-2000ALW/L probe is applicable to measure levels of liquids containing contaminants or suspensions. A typical use for this probe is the measurement of levels of liquid waste in intermediate pumping stations, fermentation chambers, settling tanks etc. Because in submersible part of level probe is mounted only measuring sensor level probe can be use for measurement hot liquids max. 120°C APC 2000ALW L

level probe PCE-28P and APC-2000ALW/P

Hydrostatic level probes are applicable to measure levels of liquids in open tanks, channels, measuring constrictions of open channels, streams etc PCE 28P and APC 2000ALW P

LEVEL SWITCHES ERH

Float level switches are used for point level detection of liquids in all type of vessels. Operation without external power, side or top mounting, wide temperature and pressure ranges, various process connections, stainless steel wetted parts, Ex version and marine certificates make it a universally applicable level switch. Level switches are available with floats in two sizes: Ø64.5 x 130mm or Ø52 x 162mm) ERH

Temperature Transmitter APT-2000ALW

Smart temperature transmitters APT-2000ALW MID is applicable to the measurement of the temperature in application designed according to directive 2004/22/WE (MID), harmonized standard PN-EN12405-1:2005 + A2:2010 and recommendation OIML R140:2007. Device subcomponent suitable for custody transfer measurement of gas with MID approval. Mechanical construction and installation of the transmitter enclosure shall comply with the transmitter APT-2000ALW are described on page IX/ 2, IX/ 3 of catalogue. Transmitter due to factory blockade of transmitter’s configuration cannot be configurable by user. Electrical connection of the transmitter is according to drawing on page IX/ 3. Available are only terminals SIGNAL + and SIGNAL -. Temperature transmitter APT-2000ALW MID are produce with GB type of sensor and with resistant sensor Pt100. Note! For custody transfer applications, the cover clamp screws have to be locked with seal wire. APT 2000ALW

TEMPERATURE DISPLAYS WW-30 T

WW-30 and WW-30T displays are applicable to cooperation with the transmitters having a standard current, voltage or resistant output signal. The WW-30, WW-30T has a configurable display range from -999 to 9999. WW-30, WW-30T can be programmed only by remote controller RC-01. User can to depute Aplisens company to progra ·m the following parameters WW 30 WW 30T

TEMPERATURE DISPLAYS - PMT-920

The programmable two relays indicator PMT-920 is designed for temperature measurement. It communicates with resistor-type Pt100 sensors where connection can be made with 2, 3 or 4-wires line. The indicator automatically recognizes a 3 or 4-wire system and compensates resistance of the sensor line. Additionally, two threshold limits can be programmed within the converter to control relay-type outputs. Exceeding the threshold actuates the outputs and is indicated on the front panel of the device. The relay-type outputs have 1 pair of NO contacts. PMT 920

Electromagnetic flow meter PEM-1000

Application Electromagnetic flowmeter for bidirectional measurement of liquids with a minimum conductivity of ≥ 5 ìS/cm:
  • Acid, alkalis 
  • Paints 
  • Pastes 
  • Water, wastewater, etc
PEM 1000

Differential pressure flowmeter

Measurement based on orifice plate with differential pressure trassmitter is most widely used type of flow measurement. It can be used in flow measurement of steam, water, and gases.

The biggest advantages of this soultion are:
  • high accuracy in wide measuring ranges
  • applicable to measure flow of neutral and agressive mediums
  • easy calibration
Differential pressure flowmeter

APIS

Simple in installation and programming Possibility of remote assembling of positioner Low air consumtion programmable speed of movement of the acutator'spiston rod Position transmitter APIS   100

APIS - Zestaw

Simple in installation and programmingPossibility of remote assembling of positionerLow air consumtion programmable speed of movement of the acutator'spiston rodPosition transmitter APIS  Zestaw

DIAPHRAGM SEALS S-P

The diaphragm seal is a pressure-transmitting, diaphragm-type device. The pressure signal is sent to the cooperating pressure measuring device (pressure transmitter, pressure gauge) through manometric liquid filling the space between the separating diaphragm of the seal and the pressure measuring device. The diaphragm seal task is to isolate the pressure measuring device from damaging impacts caused by either medium or installation:
  •  low or high temperature, increased viscosity, impurities; 
  •  vibrations of the installation (remote diaphragm seal).
DIAPHRAGM SEALS S P

DIAPHRAGM SEALS S-T

The diaphragm seal is a pressure-transmitting, diaphragm-type device. The pressure signal is sent to the cooperating pressure measuring device (pressure transmitter, pressure gauge) through manometric liquid filling the space between the separating diaphragm of the seal and the pressure measuring device. The diaphragm seal task is to isolate the pressure measuring device from damaging impacts caused by either medium or installation:
  •  low or high temperature, increased viscosity, impurities;
  •  tendency to crystallisation on the tank walls;
  •  vibrations of the installation (remote diaphragm seal).                                                                                                                  The flanged diaphragm seal with extended diaphragm is typically applied to measure the pressure or level of the media in a multi-walled tank, where the separating diaphragm should be placed close to the inner wall of the tank.
S T