level probe APC-2000ALW/L
The APC-2000ALW/L level probe is applicable to measure liquid
levels in tanks, deep wells or piezometers.
The APC-2000ALW/L probe is applicable to measure levels of
liquids containing contaminants or suspensions. A typical use
for this probe is the measurement of levels of liquid waste in
intermediate pumping stations, fermentation chambers, settling
tanks etc. Because in submersible part of level probe is mounted
only measuring sensor level probe can be use for measurement
hot liquids max. 120°C
level probe PCE-28P and APC-2000ALW/P
Hydrostatic level probes are applicable to measure levels of liquids in open tanks,
channels, measuring constrictions of open channels, streams etc
LEVEL SWITCHES ERH
Float level switches are used for point level detection of liquids in all type of vessels. Operation without external power,
side or top mounting, wide temperature and pressure ranges, various process connections, stainless steel wetted parts,
Ex version and marine certificates make it a universally applicable level switch. Level switches are available with floats in
two sizes: Ø64.5 x 130mm or Ø52 x 162mm)
Temperature Transmitter APT-2000ALW
Smart temperature transmitters APT-2000ALW MID is applicable
to the measurement of the temperature in application designed
according to directive 2004/22/WE (MID), harmonized standard
PN-EN12405-1:2005 + A2:2010 and recommendation OIML
R140:2007. Device subcomponent suitable for custody transfer
measurement of gas with MID approval. Mechanical construction
and installation of the transmitter enclosure shall comply with the
transmitter APT-2000ALW are described on page IX/ 2, IX/ 3 of
catalogue. Transmitter due to factory blockade of transmitter’s
configuration cannot be configurable by user. Electrical
connection of the transmitter is according to drawing on page
IX/ 3. Available are only terminals SIGNAL + and SIGNAL -.
Temperature transmitter APT-2000ALW MID are produce with GB
type of sensor and with resistant sensor Pt100.
Note! For custody transfer applications, the cover clamp screws
have to be locked with seal wire.
TEMPERATURE DISPLAYS WW-30 T
WW-30 and WW-30T displays are applicable to
cooperation with the transmitters having a standard current,
voltage or resistant output signal. The WW-30, WW-30T
has a configurable display range from -999 to 9999.
WW-30, WW-30T can be programmed only by remote
controller RC-01. User can to depute Aplisens company to
progra ·m the following parameters
TEMPERATURE DISPLAYS - PMT-920
The programmable two relays indicator PMT-920 is designed for
temperature measurement. It communicates with resistor-type
Pt100 sensors where connection can be made with 2, 3 or 4-wires
line. The indicator automatically recognizes a 3 or 4-wire system
and compensates resistance of the sensor line. Additionally, two
threshold limits can be programmed within the converter to control
relay-type outputs.
Exceeding the threshold actuates the outputs and is indicated on
the front panel of the device. The relay-type outputs have 1 pair of
NO contacts.
Electromagnetic flow meter PEM-1000
Application
Electromagnetic flowmeter for bidirectional measurement
of liquids with a minimum conductivity of ≥ 5 ìS/cm:
- Acid, alkalis
- Paints
- Pastes
- Water, wastewater, etc
Differential pressure flowmeter
Measurement based on orifice plate with differential pressure
trassmitter is most widely used type of flow measurement. It can be
used in flow measurement of steam, water, and gases.
The biggest advantages of this soultion are:
The biggest advantages of this soultion are:
- high accuracy in wide measuring ranges
- applicable to measure flow of neutral and agressive mediums
- easy calibration
APIS
Simple in installation and programming Possibility of remote assembling of positioner Low air consumtion programmable speed of movement of the acutator'spiston rod Position transmitter
APIS - Zestaw
Simple in installation and programmingPossibility of remote assembling of positionerLow air consumtion programmable speed of movement of the acutator'spiston rodPosition transmitter
DIAPHRAGM SEALS S-P
The diaphragm seal is a pressure-transmitting, diaphragm-type device. The pressure signal is sent to the cooperating
pressure measuring device (pressure transmitter, pressure gauge) through manometric liquid filling the
space between the separating diaphragm of the seal and the pressure measuring device. The diaphragm seal
task is to isolate the pressure measuring device from damaging impacts caused by either medium or installation:
- low or high temperature, increased viscosity, impurities;
- vibrations of the installation (remote diaphragm seal).
DIAPHRAGM SEALS S-T
The diaphragm seal is a pressure-transmitting, diaphragm-type device. The pressure signal is sent to the cooperating
pressure measuring device (pressure transmitter, pressure gauge) through manometric liquid filling the space between the
separating diaphragm of the seal and the pressure measuring device. The diaphragm seal task is to isolate the pressure
measuring device from damaging impacts caused by either medium or installation:
- low or high temperature, increased viscosity, impurities;
- tendency to crystallisation on the tank walls;
- vibrations of the installation (remote diaphragm seal). The flanged diaphragm seal with extended diaphragm is typically applied to measure the pressure or level of the media in a multi-walled tank, where the separating diaphragm should be placed close to the inner wall of the tank.